首页 站点导航 联系我们

     Series PCS,PCM                                        PDF Download  中文/English


    Measuring ranges: 100mm -3000mm
    Non linearity :± 0.025%FS ,(± 1bit )
    Resolution : 16bit, 0.05mm
    Non repeatability :± 0.02%FS ,(± 1bit )
    Operating temperature range : probe : -40 ℃ -110 ℃ 。 Measuring head : -40 ℃ -75 ℃
    Environmental protection : IP65
    Measuring channel : can reach 2 channels
    Digital RS485 : it is the standard and more convenient output
    Analog : voltages and current.(see technical speciflcation)
    Analog signals : 0-10v,10-0v,4-20ma,20-4ma,0-20ma,20-0ma
    Velocity measurements : 25 -10000mm /s


     Series PCR                                              PDF Download   中文/English
     
    Measuring ranges: 100mm -3000mm
    Non linearity :± 0.025%FS ,(± 1bit )
    Resolution : 16bit, 0.05mm
    Non repeatability :± 0.02%FS ,(± 1bit )
    Operating temperature range : probe : -40 ℃ -110 ℃ 。 Measuring head : -40 ℃ -75 ℃
    Environmental protection : IP65
    Measuring channel : can reach 2 channels
    Digital RS485 : it is the standard and more convenient output
    Analog : voltages and current.(see technical speciflcation)
    Analog signals : 0-10v,10-0v,4-20ma,20-4ma,0-20ma,20-0ma
    Velocity measurements : 25 -10000mm /s